Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13789097

- Product Categories
- Friendly Links
- home > Supply > Beilun Free Trade Zone, plus air conditioning and fluoride and ammonia there a difference? 13780045792
Beilun Free Trade Zone, plus air conditioning and fluoride and ammonia there a difference? 13780045792
Information Name: | Beilun Free Trade Zone, plus air conditioning and fluoride and ammonia there a difference? 13780045792 |
Published: | 2015-06-15 |
Validity: | 300 |
Specifications: | |
Quantity: | 1.00 |
Price Description: | |
Detailed Product Description: | Beilun central air conditioning and fluoride to teach you a few simple air conditioning and fluoride determination method of a qualified installation of air conditioning does not leak, 2035, 2078 can not fluoride. On the contrary, the three possible leaked two days. ? Users how they judge it Beilun air conditioning and fluoride center to teach you some simple ways to help you determine what generally: air conditioner a try --- normally open for some time blowing wind was cool, and can quickly reached the set temperature, the outdoor unit compressor as the refrigerator open for a while off for a while, it can said to be normal. Second test --- with inlet and outlet air temperature differential thermometer indoor unit difference is more than 10 ℃, can be considered normal, the greater the temperature difference Gree better working conditions, good up to 15 ℃. Third, look --- After ten minutes of boot to open the indoor unit panel, you should see a uniformly filled with condensate evaporator (brass wear full aluminum heat exchange components) on, www.ktjfw.cn like dew Like normal (air humidity, and more, whereas less). If half of the half did not, it may be lack of fluoride. Such as local frost or ice is not normal. Four touch --- The outdoor unit where the staff can touch, you can touch in the boot after ten minutes. The outdoor unit has two copper valves, one by thick brass, one by small brass. Touch the two valves should be the temperature difference; thicker than the thin temperature lower, feeling the cool comparison to normal (in the high temperature should also be condensate). Touching the hot outdoor unit is not the warm, if not hot may be the lack of fluoride. Five police used more than six months --- users can see whether pipe joints and valves at outdoor unit indoor unit has obvious signs of oil leakage, if obvious leakage indicates that the machine leaks, because the oil solubility fluoride, oil spill will drain fluorine, leakage of fluorine will spill. Before fluoride to repair the leak site Beilun center Tips air conditioning and fluoride, the above exception of the last, to be in the selection, installation, working conditions are normal premise, or previous work is normal, we do not. " cold ", it may be lack of fluoride. Lack of fluoride is one of the most common but not the only problems. Not have the above must be the lack of fluoride. And adds a fluorine, it will also cause indoor unit only wind but the temperature does not drop down, increased compressor load, overcurrent and other illnesses. Central air conditioning and fluoride only Beilun professional maintenance personnel through a serious and responsible testing, reference low pressure ambient temperature, voltage, current, machine hours and outlet temperature, an overall judgment has gone wrong to "remedy." Six Tips --- If the air conditioner year (within or less) you need to add fluorine, first to repair the leak site, and then add fluorine. Like bike "First Tyre, after cheer." Seven in mind --- to move or to be demolished for renovations and air conditioning of the user, and that the air conditioning before demolition must let me love my family central air conditioning and fluoride professional maintenance staff receive fluorine, and must take the open mouth with duct port and valve The original plugs plug nuts good, or to use a multi-layer plastic sheeting package Yan. If once the water or into the soil, the consequences are very serious. Damaged insulation kits also timely repair, or air conditioning energy efficiency is a lot of loss. |
Admin>>>
You are the 10063 visitor
Copyright © GuangDong ICP No. 10089450, Environmental Protection Engineering Co., Ltd. Ningbo-source All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 10063 visitor
Copyright © GuangDong ICP No. 10089450, Environmental Protection Engineering Co., Ltd. Ningbo-source All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility